Simulink block for initialization

2 次查看(过去 30 天)
In my simulink simulation, initial value of a particular constant input is to be given by me. Later on the value is changed by the feedback signal.
The feedback signal is also constant(1x1) but changes with time. My question is is there a block for this particular condition.?

采纳的回答

Dhanashree Mohite
As per my understanding, you want to use one constant value while initializing and afterwards the feedback value.
So, actually there are multiple ways. Below are some:
1. You can use unit delay block for feedback and use it’s initial condition property to set initial value.
2. You can also use triggered or enabled subsystem. You can set initial value for it’s output port. And then you can use any value as it’s input afterward.

更多回答(1 个)

Anand Shirke
Anand Shirke 2019-2-11
Block Initial Condition works like charm!

类别

Help CenterFile Exchange 中查找有关 Schedule Model Components 的更多信息

产品

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by