Simulink integrator block initial conditions

3 次查看(过去 30 天)
Hi, How does one specify initial conditions in simulink integrator block for times not t= 0 for example, y(3) =5;

采纳的回答

Fangjun Jiang
Fangjun Jiang 2019-2-5
utilize the "External reset" (set as rising) and "Initial ocndition source" (set as external).
Compare clock with t=3 and make it as the "External reset" signal.
  4 个评论
Fangjun Jiang
Fangjun Jiang 2021-4-23
Compare Clock with Constant block (value is 3) using the Relational Operator block, the output is trur or false.
Wang Tao
Wang Tao 2021-4-24
Thanks for the prompt reply! I can get the answer for the time after t=3 with the y(3)=5 now. But the problem is for the time earilier than 3 as t<3, is not correct.
I am handling some two point boundary value problem, which y(3)=5 is the end/ final condition. Is there any way to solve this.
It seems can change the initial setting of integrator through properties, but there are no final condition settings.

请先登录,再进行评论。

更多回答(0 个)

类别

Help CenterFile Exchange 中查找有关 Sources 的更多信息

产品


版本

R2018b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by