Simulink integrator block initial conditions
8 次查看(过去 30 天)
显示 更早的评论
Hi, How does one specify initial conditions in simulink integrator block for times not t= 0 for example, y(3) =5;
0 个评论
采纳的回答
Fangjun Jiang
2019-2-5
utilize the "External reset" (set as rising) and "Initial ocndition source" (set as external).
Compare clock with t=3 and make it as the "External reset" signal.
4 个评论
Fangjun Jiang
2021-4-23
Compare Clock with Constant block (value is 3) using the Relational Operator block, the output is trur or false.
Wang Tao
2021-4-24
Thanks for the prompt reply! I can get the answer for the time after t=3 with the y(3)=5 now. But the problem is for the time earilier than 3 as t<3, is not correct.
I am handling some two point boundary value problem, which y(3)=5 is the end/ final condition. Is there any way to solve this.
It seems can change the initial setting of integrator through properties, but there are no final condition settings.