Please help me to sove this problem, thank you so much!
24 次查看(过去 30 天)
显示 更早的评论
Caused by:
- PSB option menu block block (mask) does not have a parameter named 'NonlinearTolerance'
3 个评论
BAMMIDI RAVITEJA
2022-6-21
Delete Powergui block of new version and Replace with the block from your Installed Simulink library.It helped me.
Ali Hussein Numan
2024-7-6
编辑:Ali Hussein Numan
2024-7-6
Yes replace the powergui block from your Installed Simulink library with the old one
采纳的回答
Andrew
2019-6-25
This looks like an issue with your specific model saved in a previous release being opened in a newer release. Reviewing our issue tracking database, I believe this issue has been fixed in MathWorks release R2019a. Please could you try opening your model in that version, and if it doesn't work please could you directly contact MathWorks support to provide them with your model.
0 个评论
更多回答(1 个)
Yuan Ren
2019-9-11
Drag a "powergui" from the library might help.
2 个评论
Anton Shavin
2020-8-21
Same for me. Was one block from older Simulink version opened in the newer one