Simulink Real-Time - Communication on Target PC in latest versions
2 次查看(过去 30 天)
显示 更早的评论
If i am not wrong, then the support for none-Speedgoat computers has been completly removed. My problem is, that i need to upgrade an existing real-time target PC model to the latest MATLAB/Simulink version to use newer block from other Toolboxes.
As far as I understand, the real-time traget runs its own Operating System. Will this newer OS version still support the Hardware that is currently working with a R2015b Environment? I am thinking of the Intel LAN-Port in this machine and is there any chance to continue using a Softing CAN Adapter?
If all this functionality has been removed, is there a chance to recover it? For example via S-Function blocks? The vendor (Softing) offers an C/C++ API for the CAN-Interface. Does the Target PC need a driver in addition to that API ?
Thanks!
0 个评论
采纳的回答
Diego Kuratli
2019-11-10
编辑:Diego Kuratli
2019-11-14
When you upgrade MATLAB in your development PC, you have to upgrade the real-time kernel on your target machine too. In other words, you won't be able to connect your target machine with R2015b real-time kernel and your development PC with MATLAB R2019b.
Also, note that the I/O drivers are not stored in the real-time target machine or part of the real-time kernel. The I/O drivers are delivered as S-Functions (Simulink driver blocks). When you build your application, the generated code includes the I/O drivers.
更多回答(0 个)