When I open a model's test harness, I receive the following error:
I would like to disable the "ModelReferenceVersionMismatchMessage" parameter, but when I go to the configuration parameters, it's greyed-out and I can't modify it. When I try to edit it from the command line, I also receive errors:
The documentation page for this parameter doesn't give any hints as to when it is possible to actually edit it. How can I edit it?

采纳的回答

Fangjun Jiang
Fangjun Jiang 2020-4-9
Try this
model='sldemo_mdlref_basic';
open_system(model);
get_param(model,'ModelReferenceVersionMismatchMessage')
set_param(model,'ModelReferenceVersionMismatchMessage','warning')
set_param(model,'ModelReferenceVersionMismatchMessage','none')
  3 个评论
Fangjun Jiang
Fangjun Jiang 2020-4-20
Yes. In the .tlc file, you can disable certain configuration parameters. Open the .tlc file to see if you can find the source.
Monika Jaskolka
Monika Jaskolka 2020-4-20
编辑:Monika Jaskolka 2020-4-20
Thank you. You're right. I can enable the parameter by modifying the custom .tlc file like this:
slConfigUISetEnabled(hDlg, hSrc, 'ModelReferenceVersionMismatchMessage', 'true');