When is the 'ModelReferenceVersionMismatchMessage' Simulink model parameter editable?
1 次查看(过去 30 天)
显示 更早的评论
I would like to disable the "ModelReferenceVersionMismatchMessage" parameter, but when I go to the configuration parameters, it's greyed-out and I can't modify it. When I try to edit it from the command line, I also receive errors:
The documentation page for this parameter doesn't give any hints as to when it is possible to actually edit it. How can I edit it?
0 个评论
采纳的回答
Fangjun Jiang
2020-4-9
Try this
model='sldemo_mdlref_basic';
open_system(model);
get_param(model,'ModelReferenceVersionMismatchMessage')
set_param(model,'ModelReferenceVersionMismatchMessage','warning')
set_param(model,'ModelReferenceVersionMismatchMessage','none')
3 个评论
Fangjun Jiang
2020-4-20
Yes. In the .tlc file, you can disable certain configuration parameters. Open the .tlc file to see if you can find the source.
更多回答(0 个)