Svpwm 2 error block on the Equivalent model
1 次查看(过去 30 天)
显示 更早的评论
Hi, I'm trying to simulate this circuit on simunlink and I got these two errors on the equivalent model
I'm not sure what is the problem here ; it says "error in port dimensions"
Block error simulink : input is a one dimentional vector with 6 elements
0 个评论
回答(1 个)
Sabin
2023-3-13
编辑:Sabin
2023-3-13
Looks like the problem is in the Universal Bridge. The dimension of 'g' input is expected to be 6 as we have 6 switching devices in a three-phase inverter. However, in the attached image the input 'g' is connected to a Pulse Generator that outputs only a pulse. Probably it is better to use a PWM Generator that would output 6 pulses.
0 个评论
另请参阅
类别
在 Help Center 和 File Exchange 中查找有关 Electrical Block Libraries 的更多信息
产品
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!