Data Acquisition Toolbox doesn't work with Simulink
4 次查看(过去 30 天)
显示 更早的评论
Hello,
I am using the NI 9188 Chassis with different Modules for IO purpose. It works properly with Matlab and the Data Acquisition Toolbox, that means things like
myDAQ = daq.createSession('ni');
myDAQ.addAnalogInputChannel('cDAQ9188-AI' , 'ai0' , 'Voltage');
myDAQ.DurationInSeconds = measurement_time;
myDAQ.Rate = measurement_rate;
myDAQ.startForeground();
are working fine. But when I try the In- and Output Blocks within Simulink, the Blocks only say: Device: none, and I'm not able to configure anything.
I am using Windows XP with NIDAQmx Driver and Matlab 2012a. Things like daq.getVencors oder daq.getDevices are showing up the correct hardware.
What I found out is, that my Hardware is only able to deal with the session base interface. Isn't it supportet with Simulink?
Thanks for any efforts in advance.
0 个评论
采纳的回答
Pedro Villena
2012-10-29
编辑:Pedro Villena
2012-11-12
If you use Real-Time Windows Target Blockset, check if your hardware is in the list of supported hardware.
If you use xPC Target Blockset, check if your hardware is in the list of supported hardware.
Yes, Data Acquisition Toolbox provides blocks that are only available using the Legacy interface and the 32-bit version of MATLAB.
更多回答(2 个)
另请参阅
类别
在 Help Center 和 File Exchange 中查找有关 Data Acquisition Toolbox 的更多信息
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!