Error in simscape multibody "...Prismatic' has base and follower ports that are rigidly connected; it is ignored. Resolve this issue in order to simulate the model"

40 次查看(过去 30 天)
Hello.
I imported a CAD model into simscape multibody and when i try to simulate it i get this error:
Prismatic Joint 'Tracking_structure1/Prismatic' has base and follower ports that are rigidly connected; it is ignored. Resolve this issue in order to simulate the model.
Does anyone know what this error is?
Thank you

采纳的回答

Vasco Lenzi
Vasco Lenzi 2020-8-5
It seems you have a prismatic joint placed between two frames that are already directly connected, either through a connection line or because they belong to the same body. You can easily reproduce this error in a smaller model to better understand why it happens:
As you can see the prismatic joint frames B&F are connected to something that is rigidly connected (in this case is the same frame!).
The frames of a joint needs to be part of two separated body parts (usually)
Did this happens with the resulting model imported using >>smimport ?
Or did the error appeared when you modifed the imported model?
This may be due to "bad" modeling in the CAD environment where joint may have been placed simply in order to build up something, but without thoughts for thedynamc behaviour of the systems. The best way to ensure repeatable import is to address the issue in the cad environment and test the model again after importing
  3 个评论

请先登录,再进行评论。

更多回答(0 个)

类别

Help CenterFile Exchange 中查找有关 Assembly 的更多信息

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by