how to connect sum block in Simulink to both ideal switches

6 次查看(过去 30 天)
how to connect sum block in Simulink to both ideal switches as shown in figure
  2 个评论
Mohsen Aleenejad
Mohsen Aleenejad 2020-7-30
Hello Emad,
This ideal switch belongs to the Specialized Power Systems library. Terminals 1 and 2 cannot be connected to the signal ports. You should find power components/parts for those terminals like this:

请先登录,再进行评论。

采纳的回答

Mohsen Aleenejad
Mohsen Aleenejad 2020-7-30
This ideal switch belongs to the Specialized Power Systems library. Terminals 1 and 2 cannot be connected to the signal ports. You should find power components/parts for those terminals like this:
For your model, probably this is what you need to do:
Good Luck
Mohsen

更多回答(1 个)

Joel Van Sickel
Joel Van Sickel 2020-7-30
Hello Emad,
the issue here is that there are two types of wires that you are using. One is a standard simulink wire, which has the arrows indiciating flow of data. however, the other connections you are trying to use are actual electrical connections. These were designed so that you could build an actual circuit, that interacts with the more logical and math based simulink models. If you want to bring a signal from simulink into your circuit with a sum block, I would recommend using a controlled voltage source. https://www.mathworks.com/help/physmod/sps/powersys/ref/controlledvoltagesource.html
In the matlab control panel, you could type this: power_controlvolt
in order to open an example of how to use this type of block.
Regards,
Joel

社区

更多回答在  Power Electronics Control

类别

Help CenterFile Exchange 中查找有关 Switches and Breakers 的更多信息

产品

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by