All discrete sample times in your model must be an integer multiple of the local solver sample time.
6 次查看(过去 30 天)
显示 更早的评论
Anyone solve my Error:
All discrete sample times in your model must be an integer multiple of the local solver sample time.
1 个评论
Mathieu NOE
2020-10-22
Hi
If you do discrete steps simulation , simulink work at the highest sampling rate specified in your model.
You can have slower tasks, but those tasks time stamps must coincide with the time stamps of the higher sampling rate.
That's why all tasks must be running at nteger multiple of the local solver sample time.
example : fast task requires dt = 1e-3 , slower task 1 runs at dt1 = 10*dt, even slower task 2 runs at dt2 = 100*dt, etc...
look at the help for task rate transition between blocks running at different rates
回答(1 个)
Nitin Kapgate
2020-10-28
Simulating a discrete system requires that the simulator take a simulation step at every sample time hit. For a multirate discrete system (a system whose blocks Simulink samples at different rates) the steps must occur at integer multiples of each of the system sample times. Otherwise, the simulator might miss key transitions in the states of the system.
You can resolve the error by setting the sample times of different blocks as integer multiples of solver’s sample time.
0 个评论
另请参阅
类别
在 Help Center 和 File Exchange 中查找有关 Manual Performance Optimization 的更多信息
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!