Cannot add digital I/O channels although device supports it...
1 次查看(过去 30 天)
显示 更早的评论
Hi,
I'm using a NiDAQ PCI 6722. This device supports digital I/O and I verified this using NI software.
However, when I start a DAQ session, I cannot add a digital channel. Only analog channels are allowed and the methods for adding digital channels are not even listed in the session object.
How do I get DAQ to recognize my hardware?
Thanks, Matt
2 个评论
Walter Roberson
2013-2-21
Which MATLAB version are you using?
To confirm, you are using the session-based interface ?
回答(1 个)
Walter Roberson
2013-2-24
At least part of the functionality for the 6722 needs R2012b. https://www.mathworks.com/products/daq/supported/ni-daqmx.html