Link blocks in different libraries[Fuel Cell Stack(Specialized power system) and Motor & Drive (Simscape electrical)

2 次查看(过去 30 天)
The two blocks contained in the two libraries with red circle respectively.
I want to link the two blocks together as they are the key components in my model. However, it failed as they located in differrent libraries.(one with the Blank square port another with the gray one).
Could anyone tell me how to link the two components together(like use a converter to transform the data) or if there's any substitute for the two blocks that in the same libraries?

采纳的回答

Guanwei Zeng
Guanwei Zeng 2021-3-11
I fonund this bolck is more efficient as it can transform the signal directly.
https://www.mathworks.com/help/physmod/sps/interface-to-simscape.html

更多回答(1 个)

Guanwei Zeng
Guanwei Zeng 2021-3-11
Finally, I found a solution. First, measure the voltage of the Fuel Cell Stack and use the Simulink-PS converter to transform the electrical signal to a Simulink signal. Then connect the Simulink Signal to a controlled voltage scource in Simscape(not the one in specialized electrical system). In this way, the controlled voltage scource and PMSM ar ein the same library.

类别

Help CenterFile Exchange 中查找有关 Specialized Power Systems 的更多信息

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by