Error while connecting to realtime target
2 次查看(过去 30 天)
显示 更早的评论
Hi, I made level 2 s-function in C language, which sends some data via serial port. I compiled it with Microsoft Visual C++ 2008 SP1 compiler. When I add this s-function to simulink model and start the simulation in normal mode, everything is ok, but, when I want to connect with realtime target (after building with rtwin.tlc), I get this error message:
Error occurred while executing External Mode MEX-file 'rtwinext': Error loading real-time executable: undefined symbol "_InterlockedExchangeAdd"
I have not any idea, what this error means. Could anybody help me? Thanks.
2 个评论
Kaustubha Govind
2013-6-4
Do you think the failure is specific to your S-function, or do you see it even without your S-function. For example, you could try the example model 'rtvdp' and see if you can execute that in external mode successfully.
采纳的回答
Jan Houska
2013-6-5
For serial port communication, please use Packet Output or Stream Output blocks, depending on your data format. You are correct that you cannot use Windows API in real-time code.
更多回答(1 个)
Jan Houska
2013-6-6
If you want to react to individual received bytes, it is probably best to sample (poll) the input fast enough. I'd recommend the Packet Input block with a sample rate of, say, 0.5ms, and using its Data Ready output to trigger any necessary action.