Shimmer MATLAB Instrument Driver
编者注: Popular File 2015
Introduction
The Shimmer Matlab Instrument Driver package is a set of Matlab .m files designed to assist users of the Shimmer2, Shimmer2r, Shimmer3 and Verisense in the development of Shimmer based applications in Matlab. Please proceed to for Verisense.
For Shimmer 3 devices to begin using the Shimmer Matlab Instrument Driver please refer to the Shimmer Matlab Instrument Driver User Manual. In order to communicate changes more effectively we will be transitioning to the use of Github and will no longer be updating the user guide from Rev2.9 onwards. We will maintain providing keeping the user guide in the repository for Shimmer3 users.
Rev2.9
Release date 17/06/2022
Changes since Rev 2.8
Modifications
Added Verisense tools
Readme updated
User guide added to resource folder
Revision History
Rev0.1 is the original beta release.
Release date 02/02/2012.
Rev0.2 is the original beta release with bug fixes and minor
modifications. Release date 17/02/2012.
Changes since Rev 0.1
Known Bugs
Bug ID. 0.1.1 Bug Description: Trying to disconnect when already disconnected generates an error. Bug Status: Fixed.
Bug ID. 0.1.2 Bug Description: Issue with boolean() variable in Matlab 2011 and earlier. Bug Status: Fixed.
Bug ID. 0.1.3 Bug Description: Wait for acknowledgment timing out on some systems. Changed ShimmerHandleClass.m -> DEFAULT_TIMEOUT value from 5 secs to 8 secs. Bug Status: Fixed.
Modifications
ShimmerHandleClass.m -> waitforack Added tic/toc to improve accuracy of timeout functionality
Minor updates and corrections to Matlab Library User Manual
Rev0.3 is the original beta release with bug fixes and minor
modifications. Release date 27/02/2012.
Changes since Rev 0.2
Known Bugs
Bug ID. 0.2.1 Bug Description: Error check failed to isolate corrupt packets. Bug Status: Fixed.
Bug ID. 0.2.2 Bug Description: Byte sequence 13 10 was being interpreted as 'carriage return' 'newline' and 13 was being automatically removed. Bug Status: Fixed.
Modifications
plotandwriteexample.m Data is now written in tab delimited format as opposed to comma delimited format.
Minor updates and corrections to Matlab Library User Manual
Rev0.4 is the original beta release with bug fixes and minor
modifications. Release date 29/02/2012.
Changes since Rev 0.3
Modifications
Name change from Shimmer Matlab Library to Shimmer Matlab Instrument Driver.
Appropriate changes to User Manual to reflect name change.
Rev0.5 is the original beta release with a bug fix
Release date 24/04/2012.
Changes since Rev 0.4
Known Bugs
Bug ID. 0.4.1 Bug Description: Magnetometer signal erroneous when expected value is negative. Bug Status: Fixed.
Rev1.0 is the first full release. It is based on the original beta release
with significant additions to the functionality. The additions include the ability to retrieve both uncalibrated and calibrated data and a method to check for any dropped packets.
Release date 03/07/2012.
Changes since Rev 0.5
Known Bugs
Bug ID. 0.5.1 Bug Description: Sensors are all enabled when the Heart Rate sensor is enabled. Bug Status: Fixed.
Added the following functions:-
getcalibrationparameters getacceldata calculatetwoscomplement getgyrodata getmagdata gettimestampdata getecgdata getemgdata getexpboarddata getstraingaugedata getgsrdata getheartratedata getenabledsensors calibrategsrdata calibrateinertialsensor calibratetimestampdata getpercentageofpacketsreceived getdata
Rev1.1
Release date 13/08/2012.
Changes since Rev 1.0
Known Bugs
Bug ID. 1.0.1 Bug Description: Any sampling rate above 255Hz is stored as 255. Bug Status: Fixed.
Rev1.2
Release date 13/08/2012.
Changes since Rev 1.1
Known Bugs
Bug ID. 1.1.1 Bug Description: Any sampling rate above 255Hz is stored as 255 when an inquiry is done. Bug Status: Fixed.
Rev1.3
Release date 21/02/2013.
Changes since Rev 1.2
Modifications
The command setpmux has been set to a private function, the pmux is set automatically now depending on whether battery voltage monitoring or Exp Board is enabled. To enabled batt voltage monitoring the following methods were updated/made
- getdata
- getenabledsignalnames
- getbattvoltdata
- setexternalboard
- setenabledsensors
- updated get calibration methods, now returns the com port when a shimmer device is not calibrated
- the gsr calibration method has been updated
- accel calibration parameters have been updated
- default accel calibration parameters for all ranges have been added
- default alignment for accel has been updated
- warning msgs concerning crosstalk when using accel + exp board a7 added
- warning msg concerning calibration parameters when setting a different accel range
Known Bugs
Bug ID. 1.2.1 Bug Description: setpmux and setfivevoltreg command not working. Bug Status: Fixed.
Rev1.4
Release date 20/03/2013.
Changes since Rev 1.3
Modifications
- Battery monitoring
- Low Battery notification (only usable with BTStream)
- get ecg,emg,all calibration parameters
- write ecg and emg calibration parameters
- Firmware version now supported (Boiletplate 0.1 and BTStream 1.0), note that Boilerplate is now considered legacy firmware
- Updates to Heart Rate to support BTStream 1.0 which now sends a 2 byte value, indicating when the pulse occured and the time duration between the curent pulse and the previous one
- ECG and EMG units are mVolts* when default calibration parameters are used
Rev1.5
Release date 27/06/2013.
Changes since Rev 1.4
Modifications
- Magnetometer configuration (range and data rate).
- 3D orientation estimation (in quaternion format); note that accel, gyro and mag must be enabled.
- New example: orientation3Dexample.m.
- Gyro in-use calibration method to update offset bias vector.
- Added function to set buffer size; this is called from shimmer.connect().
- Fixed FirmwareVersion to take a non-integer value.
Rev1.6
Release date 27/06/2013.
Changes since Rev 1.5
Modifications
- Updated to work with Shimmer3
Rev1.7
Release date 11/10/2013.
Changes since Rev 1.6
Modifications
- Updated to work with BTStream and Boilerplate
- Fixed twos complement method
Rev1.8
Release date 14/10/2013.
Changes since Rev 1.7
Modifications
- Added pressure sensor support for Shimmer3
Rev1.9
Release date xx/xx/2013.
Changes since Rev 1.8
Modifications
- Updated twos complement method because current use of BITCMP(x,n) is being deprecated
- Updated code to support Low Noise Accel and Wide Range Accel
- Updated getdata method to check whether there is any data read from the buffer, before processsing the data
- Added GSR support for Shimmer3
- Added minor support for EXG for internal testing, users should wait for official release
Rev2.0
Release date 29/01/2014.
Changes since Rev 1.9
Modifications
- Removed old folders (fw) and old scripts which dont belong
Rev2.1
Release date 21/03/2014.
Changes since Rev 2.0
Modifications
- ExG support for Shimmer3 (including examples)
- Add battlimitwarning for Shimmer3
- Revised comments and warnings
Rev2.2
Release date 01/07/2014.
Changes since Rev 2.1
Modifications
- Bridge Amplifier support for Shimmer3 (Shimmer2/2r equivalent is known as Strain Gauge)
- Improved filter implementation (using FilterClass.m)
- Functions for setting wide-range accelerometer high resolution and low power modes for Shimmer3
- Compatibility change signal names accelerometers (User Manual section 'Differences between Shimmer2r and Shimmer3')
- Use of macros for enabling sensors
- Function specific warnings
- Revised comments
- pppgtoheartrateexample (Heart Rate from Photo Plethysmograph)
- Improved existing examples
- Firmware compatibility codes
Rev2.3
Release date 13/10/2015.
Errata
- Version number in ShimmerHandleClass was not updated (v2.2)
Changes since Rev 2.2
Modifications
- Added SetEnabledSensorsMacrosClass, disableallsensors() - for easier enabling/disabling sensors.
- Improved existing examples.
- orientation3Dexample - Changed orientation of Shimmer visualisation for Shimmer3.
- Added small description for all lower level functions.
- New getdata(), deprecated old function to depricatedgetdata()
- ExG lead-off support
- Get Expansion Board ID support
- LogAndStream FW support
- Configurable Baudrate support
- ecgtoheartrateexample (Heart Rate from ECG)
- plotandwriteecgleadoffdetectionexample
- plotandwriteemgleadoffdetectionexample
Fixed Bugs
- 16BIT ExG is parsed incorrectly - interpretdatapacketformat()
- Strain Gauge data incorrectly calibrated; gain was multiplied by a factor 2.8, while this should be a factor 1.
- Bridge Amplifier+ data incorrectly calibrated; gain was multiplied by a factor 2.8, while this should be a factor 1.
- Incorrect default calibration parameters Shimmer3 magnetometer. (Minor impact: for a few ranges test values were used instead of default values from datasheet, alignment matrix was multiplied by -1.)
Rev2.4
Release date 06/03/2015.
Changes since Rev 2.3
Modifications
- Added resettodefaultconfiguration() - resets Shimmer default configuration for Shimmer3.
- Class properties are now updated when setconfigbytes() / setconfigbyte0() is called.
- Autoset data rates of Wide Range Accel, Gyro, Mag and ExG when Shimmer sampling rate is set.
Fixed Bugs
- getorientation3D() - wrong variablename internalBoard.
- parseinquiryresponse() - class property ConfigByte1 incorrectly updated.
Rev2.5
Release date 12/05/2015.
Changes since Rev 2.4
Modifications
- Changed recommended filter cut-off frequency to 5Hz in plotandwriteemgexample
- Update: ShimmerBiophysicalProcessingLibrary_Rev_0_8.jar
- getgsrdata() -> reverted back to Shimmmer2r values for Shimmer3
- Modified getpercentageofpacketsreceived() to accommodate for minor possible variations in internal Shimmer clock
Fixed Bugs
- Updated readfirmwareversion to be compatible with versions > 0.6.0/0.4.0 of BtStream/LogAndStream.
- Fixed bug in estimategyrooffset() for the case when GyroBuffer = [0 0 0];
- DAccelCalParametersOV / DAccelCalParameterSM / DAccelCalParametersOVAM had Shimmer2r values -> changed to Shimmer3 values (2g range).
- Added missing case for getaccelrange==0 in getcalibrationparameters().
Rev2.6
Release date dd/mm/yyyy.
Changes since Rev 2.5
Modifications
- Updated/corrected help comments for getdeprecateddata()/getdata().
- Updated ShimmerBiophysicalProcessingLibrary + Readme to Rev_0_10.
- Updated ecgtoheartrateexample for new version of ShimmerBiophysicalProcessingLibrary - with improved ECGtoHR algorithm.
- Updated and renamed LogAndStream statuses.
- For firmware compatibility code >= 6:
- Three byte timestamp.
- Added get battery voltage command (for 'Connected' state - new instream command response).
- For LogAndStream FW:
- Added get/set/read/write functions for Real Word Clock (RWC) on Shimmer.
- Added new Action Methods for start/stop 'logging only'; stop 'logging+streaming' -> 'stop' now only stops streaming.
- For LogAndStream FW:
- For firmware compatibility code >= 7:
- Disable periodic streaming of Battery Voltage; not supported.
- Added enabletimestampunix() - enable to:
- get system (PC) timestamp for last sample in each serial buffer.
- add 'Time Stamp Unix' channel to data after 'Time Stamp' - 'Nan' between consecutive system timestamps.
- Added convertUnixTimeMillisecondsToMatlabTime() / convertMatlabTimeToUnixTimeMilliseconds()
Rev2.7
Release date 14/08/2017.
Changes since Rev 2.6
Modifications
- Added support for new IMU/BMP sensors. Based on 'HardwareCompatibilityCode', see determinehwcompcode().
- Added Pressure/temperature example - BMP180/BMP280.
- Minor comment fixes in examples.
- Updated getexpboardid() - for SR31 and unified boards: SR47-49.
- setaccelrate() - added rate setting '9' - 1344Hz for LSM303DLHC.
Rev2.8
Release date 19/09/2017.
Changes since Rev 2.7
Modifications
- Bugfix -> HardwareCompatibilityCode for Shimmer3 IMU (SR31).
- Minor other bugfixes.
- Examples now also write signal format/units to file.
引用格式
Shimmer Engineering Team (2024). Shimmer MATLAB Instrument Driver (https://github.com/ShimmerEngineering/Shimmer-MATLAB-ID/releases/tag/v2.9.0), GitHub. 检索时间: .
MATLAB 版本兼容性
平台兼容性
Windows macOS Linux类别
- Test and Measurement > Instrument Control Toolbox > Instrument Control Toolbox Supported Hardware >
- Industries > Medical Devices > Cardiology >
标签
社区
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!Resources
VerisenseTools
quaternion
版本 | 已发布 | 发行说明 | |
---|---|---|---|
2.9.0 | See release notes for this release on GitHub: https://github.com/ShimmerEngineering/Shimmer-MATLAB-ID/releases/tag/v2.9.0 |
||
2.8.0.0 | Changes since Rev 2.7
Modifications
|
||
2.7.0.0 | v2.7
|
||
2.6.0.0 | v2.6 - for full compatibility use with FW: BtStream 0.8.0 / LogAndStream 0.6.0
|
||
2.5.0.0 | v2.5
|
|
|
1.11.0.0 | v2.4 - for full compatibility use with FW: BtStream v0.5.0 / LogAndStream v0.3.0.
|
|
|
1.10.0.0 | v2.3 - for full compatibility use with FW: BtStream v0.5.0 / LogAndStream v0.3.0. - ExG lead-off support
|
|
|
1.9.0.0 | Re-uploaded rev2.2 |
||
1.8.0.0 | Please note that BtStream firmware v0.4.0 or later is required for Bridge Amplifier functionality. Please download from www.shimmersensing.com. |
||
1.7.0.0 | - ExG support for Shimmer3 (including examples)
|
||
1.6.0.0 | Removed unused scripts and folders, users should note that, BTStream firmware is required on the Shimmer device when using the Instrument Driver. Latest Version of BTStream should always be used, and is readily available on our website. |
||
1.5.0.0 | Rev 1.9
|
||
1.3.0.0 | Rev 1.8
|
||
1.2.0.0 | v1.7
|
||
1.0.0.0 |