Heat Exchanger Solver

版本 1.0.0.0 (2.4 KB) 作者: Seyyed Ali
Calculating outlet temperatures of a Heat Exchanger using Epsilon-NTU method
4.3K 次下载
更新时间 2014/4/21

查看许可证

The main function is HeatExchanger.m that calculates the outlet temperatures of a heat exchanger using Epsilon-NTU (E-NTU) method. This function uses effectiveness.m as a function and should have access to it.
The inputs are as follows:
Hot Flow: c_p_hot, m_dot_hot, T_hot_in.
Cold Flow: c_p_cold, m_dot_cold, T_cold_in.
Heat exchanger design parameters: U,A, HE_Type.
HE_Type defines the type of heat exchanger: (see reference)
  'Parallel Flow'
  'Counter Flow'
  'One Shell Pass'
  'N Shell Pass'
  'Cross Both Unmixed'
  'Cross Cmax Mixed'
  'Cross Cmin Mixed'
The second function is effectiveness.m which calculates the effectiveness of a heat exchanger : epsilon = f(NTU,C_r)
See Reference for definitions.
Third file is a test script that shows an example of using this function.
Reference:
Frank P. Incropera, Introduction to heat transfer. New York:Wiley, 1985, Section 11.4.

引用格式

Seyyed Ali (2024). Heat Exchanger Solver (https://www.mathworks.com/matlabcentral/fileexchange/46303-heat-exchanger-solver), MATLAB Central File Exchange. 检索来源 .

MATLAB 版本兼容性
创建方式 R2013a
兼容任何版本
平台兼容性
Windows macOS Linux
致谢

启发作品: Heat exchanger

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!
版本 已发布 发行说明
1.0.0.0