已回答
How to create a Simscape custom component with 2 different thermal liquids?
Hi Jérémie, The error was complaining about that two stream of fluids are mixing into each other inside your heat exchanger :p ...

4 months 前 | 2

| 已接受

已回答
How do I get the right vector of spring coefficients for the nonlinear translational spring?
Hi Emefun, A couple of things to fix: (1) add mass blocks. The "dynamic variable derivatives" error is most likely referring ...

4 months 前 | 0

| 已接受

已回答
Are Flooded Evaporators modeled already?
Hi Pablo, To the best of my knowledge, there isn't a block designed specifically for this type of heat exchanger, with coolant/...

5 months 前 | 1

| 已接受

已回答
Add "Block Parametrization Manager" to custom ssc block for Simscape
It's not supported for your use case here. Consider put together a custom Simulink library instead, where you can store and loc...

5 months 前 | 0

| 已接受

已回答
Simulation of two phase fluid with Simscape - pressure behavior unexplicable
Hi Marcel, The port area parameter of the Receiver Accumulator block doesn't affect the pressure drop between inside and outsid...

5 months 前 | 0

已回答
MATLAB/Simulink/Simscape:Contact force analysis
You can only to "Convex Hull" for generic geometry (e.g. a stp file). It may or may not be good enough for your contact force m...

5 months 前 | 0

| 已接受

已回答
The Excavator Hydraulic Jack Forces are Changing Direction in Simscape Multibody
The way the joints are actuated and the joint forces are sensed for inverse dynamic analysis looks OK. As a position signal is ...

5 months 前 | 1

| 已接受

已回答
Fluid inertia in Simscape hydraulic
Hi Amodio, I don't think the actuator blocks model the inertia of the fluid inside. The "cushion" can be used to model some en...

5 months 前 | 0

已回答
Center of mass of a free-floating body in Simscape Multibody is moving with no external forces
I believe there can be many solutions that would satisfy the initial conditions you have set. The only target set here is the s...

5 months 前 | 0

| 已接受

已回答
Flow rate discrepancy between upstream and downstream of orifice model.
A diffential pressure 2950 psi sounds big enough to change the density of the fluid. As the density changes, volumetric flow ra...

5 months 前 | 0

已回答
Simscape Fluids model of closed system
Hi Jeremy, Looks to me like an initialization issue. I don't have R2020b on my computer so I tried this on R2021b, the oldest ...

5 months 前 | 0

已回答
How to make a revolute joint turn in one direction in Simscape?
There may be better solutions, but just some ideas. If you have access to Simscape Driveline, there is a one-way clutch (Unid...

5 months 前 | 0

已回答
Pressure drop of a two-phase fluid pipeline in simscape
You can view the Simscape code of the Pipe (2P) block, save a copy, and modify it to use a custom correlation if you like. Find...

5 months 前 | 0

| 已接受

已回答
Can "pipe(G)" block be used to model forced air convection?
I think it's possible. The combination of cross section and hydraulic diameter will give you a circumference; that multiplied b...

5 months 前 | 0

| 已接受

已回答
HOW CAN I TURN AN EQUATION INTO COMPONENT IN A LIBRARY?
Hi Usha, In addition to Ayush's answer, I suggest that you look at the source code of a translational spring block. You custom...

5 months 前 | 1

已回答
How does simscape caculate the hydraulic pressure?
The pump blocks in Simscape Fluids models the flow rate at different pressure difference and speed, but themselves are "volume-l...

5 months 前 | 0

已回答
state flow入门之旅中的诸多疑问
应该是workspace的问题,红色阴影表示有缺失的参数值。Simulink模型的参数可能在 Base Workspace, Model Workspace 或者是 mask local workspace (你这里不会是最后这个情况),可以参考这个文档:...

6 months 前 | 0

已回答
Use Simscape parameter as variable in Simulink model
If it's in the Simscape Results Explorer, you should be able to use a Probe block to make it available during simulation as a Si...

6 months 前 | 0

已回答
Using the TL-2P heat exchanger in simscape to simulate an external threaded tube heat exchanger
The way you set up the heat exchanger looks promising to me. I would use the Parameter Estimator App (Documentation) to estimat...

6 months 前 | 0

| 已接受

已回答
why are the results different from moist air domain(MA) using only dry air and gas domain(G)? - simscape
Hello, Given the range of temperature you'd like to implement, I believe you are seeing the difference in the way the specific ...

6 months 前 | 1

已回答
The sum of the 2 branches flow is different than pump flow
Hi Flavio, I looked at the model and below are my observations. the parameters and inputs for the pump look ridiculous: at 1m^...

6 months 前 | 2

| 已接受

已回答
Simscape 4-Way 3-Position Directional Valve (IL) No "Fluids/Plot Valve Characteristics" Option
See the comment section for the discussion. Issue resolved (by itself) as of now.

6 months 前 | 0

已回答
Pipe (TL) fluid compressibility problem
See this related question for a more detailed discussion: https://www.mathworks.com/matlabcentral/answers/2111661-rservoir-tl

7 months 前 | 0

| 已接受

已回答
Rservoir (TL)
Hi Karim, I did a few things that feel like best practices to me: (1) add a Tank (TL) block to where the reservoir was. Pleas...

7 months 前 | 0

| 已接受

已回答
Heat Exchanger (TL-TL) breaking thermodynamics?!
This shouldn't happen for parallel-flow heat exchangers, because of 2nd law of thermo-dynamics. But this may happen for counter...

8 months 前 | 1

| 已接受

已回答
hydraulic circle for fire suppression system clean agent
Hi Albara, It will be helpful if you could provide some schematic to show the interior of the agent tank so we can understand t...

8 months 前 | 0

已回答
Simscape Gas Inertia block
Hi Caleb, "Fluid inertia is negligible." is one of the model assumption of the Pipe (G) block. You may be able to modify the c...

8 months 前 | 0

已回答
Simscape fixed displacement pump pressure gain wrong?
Hi Sandro, one quick thing to fix: you need another reservoir at port B, otherwise the fluid has nowhere to go. The reservoir a...

8 months 前 | 0

已回答
Modeling a pressurized flexible body (balloon) in simscape multibody/fluids
Hi Siril, I feel the problem may be way more complicated than just "the two open red open wires". To model this pressurized fl...

8 months 前 | 0

| 已接受

已回答
Isothermal Fluids Pump/Motor Case Drain
Hi Philip, I feel the way you model it is very reasonable. Adding an small orifice or check valve mimics what happens in real ...

8 months 前 | 0

加载更多