fread

Read binary data from instrument

Syntax

A = fread(obj)
A = fread(obj,size)
A = fread(obj,size,'precision')
[A,count] = fread(...)
[A,count,msg] = fread(...)
[A,count,msg,datagramaddress] = fread(obj,...)
[A,count,msg,datagramaddress,datagramport] = fread(obj,...)

Arguments

obj

An interface object.

size

The number of values to read.

'precision'

The number of bits read for each value, and the interpretation of the bits as character, integer, or floating-point values.

A

Binary data returned from the instrument.

count

The number of values read.

msg

A message indicating if the read operation was unsuccessful.

datagramaddress

The address of the datagram sender.

datagramport

The port of the datagram sender.

Description

A = fread(obj) and A = fread(obj,size) read binary data from the instrument connected to obj, and returns the data to A. The maximum number of values to read is specified by size. If size is not specified, the maximum number of values to read is determined by the object's InputBufferSize property. Valid options for size are:

n

Read at most n values into a column vector.

[m,n]

Read at most m–by–n values filling an m–by–n matrix in column order.

size cannot be inf, and an error is returned if the specified number of values cannot be stored in the input buffer. You specify the size, in bytes, of the input buffer with the InputBufferSize property. A value is defined as a byte multiplied by the precision (see below).

If obj is a UDP object and DatagramTerminateMode is off, the size value is honored. If size is less than the length of the datagram, only size values are read. If size is greater than the length of the datagram, a warning is issued stating that a complete datagram was read before size values was reached.

A = fread(obj,size,'precision') reads binary data with precision specified by precision.

precision controls the number of bits read for each value and the interpretation of those bits as integer, floating-point, or character values. If precision is not specified, uchar (an 8-bit unsigned character) is used. By default, numeric values are returned in double-precision arrays. The supported values for precision are listed below in Tips.

[A,count] = fread(...) returns the number of values read to count.

[A,count,msg] = fread(...) returns a warning message to msg if the read operation was unsuccessful.

[A,count,msg,datagramaddress] = fread(obj,...) returns the datagram address to datagramaddress if obj is a UDP object. If more than one datagram is read, datagramaddress is ' '.

[A,count,msg,datagramaddress,datagramport] = fread(obj,...) returns the datagram port to datagramport if obj is a UDP object. If more than one datagram is read, datagramport is [ ].

Tips

Before you can read data from the instrument, it must be connected to obj with the fopen function. A connected interface object has a Status property value of open. An error is returned if you attempt to perform a read operation while obj is not connected to the instrument.

If msg is not included as an output argument and the read operation was not successful, then a warning message is returned to the command line.

The ValuesReceived property value is increased by the number of values read, each time fread is issued.

Note

To get a list of options you can use on a function, press the Tab key after entering a function on the MATLAB® command line. The list expands, and you can scroll to choose a property or value. For information about using this advanced tab completion feature, see Using Tab Completion for Functions.

Rules for Completing a Binary Read Operation

A read operation with fread blocks access to the MATLAB Command Window until

  • The specified number of values is read. For UDP objects, DatagramTerminateMode must be off.

  • The time specified by the Timeout property passes.

  • A datagram is received (for UDP objects only when DatagramTerminateMode is on).

  • The input buffer is filled.

  • The EOI line is asserted (GPIB and VXI instruments only).

  • The EOSCharCode is received (GPIB and VXI instruments only).

More About the GPIB and VXI Terminator

The EOSCharCode property value is recognized only when the EOSMode property is configured to read or read&write. For example, if EOSMode is configured to read and EOSCharCode is configured to LF, then one of the ways that the read operation terminates is when the line feed character is received.

If EOSMode is none or write, then there is no terminator defined for read operations. In this case, fread will complete execution and return control to the command when another criterion, such as a timeout, is met.

Supported Precisions

The supported values for precision are listed below.

Data Type

Precision

Interpretation

Character

uchar

8-bit unsigned character

schar

8-bit signed character

char

8-bit signed or unsigned character

Integer

int8

8-bit integer

int16

16-bit integer

int32

32-bit integer

uint8

8-bit unsigned integer

uint16

16-bit unsigned integer

uint32

32-bit unsigned integer

short

16-bit integer

int

32-bit integer

long

32- or 64-bit integer

ushort

16-bit unsigned integer

uint

32-bit unsigned integer

ulong

32- or 64-bit unsigned integer

Floating-point

single

32-bit floating point

float32

32-bit floating point

float

32-bit floating point

double

64-bit floating point

float64

64-bit floating point

Version History

Introduced before R2006a

expand all

See Also