Limitations with Multicore Programming in Simulink
The following limitations apply when partitioning a model for concurrent execution.
Configure the model to use the fixed-step solver.
These model settings should not be used for models in the concurrent execution environment:
External mode for Mac desktop targets.
Logging to MAT-files (MAT-file logging check box selected). However, you can use the To Workspace and To File blocks.
If you are simulating your model using Rapid Accelerator mode, the top-level model cannot contain a root level Inport block that outputs function calls.
In the Configuration Parameters dialog box, set the Diagnostics > Sample Time > Multitask conditionally executed subsystem and Diagnostics > Data Validity > Multitask data store parameters to
error
.
If you want to use explicit partitioning, at the root level of your model, the model must consist entirely of
Models that are referenced using Model blocks
Subsystem blocks
MATLAB® System blocks
MATLAB Function blocks
Stateflow® charts
Rate Transition blocks
Virtual connectivity blocks
The following are valid virtual connectivity blocks: