How do I disable warnings about scope signals in referenced models (Simulink)?
1 次查看(过去 30 天)
显示 更早的评论
Using Simulink in Matlab 2011b, I get warnings like the following:
tb_SAR_ADC8x/Model|SAR_ADC8X/Model5: Warning: The model 'SAR_ADC_flat' is referenced in Normal mode
and contains the Signal Viewer scope 'SAR_ADC_flat/Scope'. This scope can display signals only if the
scope is already open when simulation begins.
I want to keep my scope signals in the sub-models for debugging them, yet I am ok that I don't see them when I reference these models in a higher level model. But I don't want a ton of useless warnings about it.
I've tried to turn off these warnings by setting Configuration...->Diagnostics->Model Referencing->Unsupported Data Logging to 'none', which from the docs seemed like it concerned signals sent to a scope too. But this brought me no luck.
Any idea how to get rid of these warnings in referenced models, hopefully without removing all the signals from the scope in the referenced model?
thanks, Matt
0 个评论
采纳的回答
Zack Peters
2013-11-9
Hi Matt,
If you cannot find it within the model's configuration parameters -> diagnostics pane, then I would take a look at our documentation and examples on "Suppressing Warnings".
~Zack
更多回答(0 个)
另请参阅
类别
在 Help Center 和 File Exchange 中查找有关 Simulink Environment Customization 的更多信息
产品
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!