Invalid Output times specified in the Configuration Parameters dialog for block diagram 'untitled1'

158 次查看(过去 30 天)
I am trying to simulate the attached model but it gives the above error. How can I solve it.
Please advise about the type and solvers suitable for the attached model

回答(4 个)

Jaime Alcón Casillas
Goog morning to all,
I have already solved that problem. I had that problem yesterday and i needed one day to know where is the problem.
In the "Configuration parameters" from simulink you just need to change the solver options to "Fixed-Step" and it will work
Regards to all

Xidong WEI
Xidong WEI 2016-11-22
if you use produce additional point, you should fill the blank named output times which is after the output options. Did you fill it?

Shaz Shah
Shaz Shah 2022-5-25
haii everyone ..
Error evaluating expression '1 e-5 ' for 'AbsTol' specified in the Configuration Parameters dialog for block diagram 'TRMS4SigmoidPID_simulink'.
can i know how to solve this problems its same with above?
  4 个评论
Walter Roberson
Walter Roberson 2022-5-26
That would be a different error message, though. I can tell from the error that it is complaining about an invalid subscript, but without more detail I cannot tell if it is complaining about subscript out of range or if it is complaining about the subscript not being an integer. You should put in a breakpoint at that line and execute to there, and check size(yout), size(yout{jj}) and check the value of tend

请先登录,再进行评论。


Haroon Zafar
Haroon Zafar 2022-11-13
Change configuration parameter setting for output options. See attched screenshots. First one is the actual setting in the untitled1.mdl file.
Chage additionl settings>>>> Output options to Refine
It might create algeabaric loop that can be autocorrected.