Discretizing a continuous state model for use in HIL
1 次查看(过去 30 天)
显示 更早的评论
I have developed a model with continuous integrators. To discretize them, i had replaced them with discrete integrators,its working fine for Ts=1e-4, but i need to use Ts=1e-3; where its not getting simulated properly.
Anyone any suggestions,please post. Thanks
0 个评论
回答(1 个)
Azzi Abdelmalek
2013-11-27
You didn't precise how you replaced the other blocks, and I don't think you are doing the right thing. You also did not give enough information about your model (linear or not for example). If your model is linear you can use the function c2d to discretize it.
3 个评论
Azzi Abdelmalek
2013-11-27
To be sure that you are doing the right thing, don't replace any block, just put a ZOH block with desired sample time after each output of your model (if your model is mimo) and before each input. Another important thing is: how did you choose the sample time, you can't set any sample time you want, it depends on the dynamic of your model, maybe 1e+3 is too large