i am trying to get emg and force data simultaneously using parallel computing tool box but i am unable to read the data???

2 次查看(过去 30 天)
i am using the below code
if matlabpool('size') == 0
matlabpool open local 2
data1=zeros([122880,2]);
data2=zeros([37000,1]);
spmd
switch labindex
case 1
s = daq.createSession('ni');
s.addAnalogInputChannel('cDAQ2Mod1', 0, 'Voltage');
s.addAnalogInputChannel('cDAQ2Mod1', 1, 'Voltage');
s.Rate = 2048
s.DurationInSeconds = 60;
labBarrier
[data1,time] = s.startForeground;
case 2
delete(instrfindall);
s = serial ( 'COM5', 'BaudRate', 115200);
set(s, 'Timeout',60);
s.InputBufferSize =37000;
labBarrier
fopen(s);
data2=fread(s);
end
end
end
matlabpool close
my workspace is containing data in composite form
data1 composite
data2 composite
is there any way to solve this problem???
  5 个评论
avinash pabbireddy
avinash pabbireddy 2013-12-2
Error using Composite/subsref (line 48) An invalid indexing request was made
Error in sync (line 44) E=data1(:);
Caused by: Error using Composite/subsref>iCheckValuesExist (line 86) The Composite has no value on the following lab(s): 2 .

请先登录,再进行评论。

采纳的回答

Edric Ellis
Edric Ellis 2013-12-4
The data contained within a Composite is retained on the workers. Therefore if you close the pool, the data goes away. So, you simply need to avoid closing the pool until you've got the data from the workers. One way to do this would be:
data1 = data1(:);
data2 = data2(:);
matlabpool close
Or, you could simply leave the matlabpool open.
  7 个评论

请先登录,再进行评论。

更多回答(0 个)

类别

Help CenterFile Exchange 中查找有关 Timing and presenting 2D and 3D stimuli 的更多信息

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by