why NAN happend when i use another signal

1 次查看(过去 30 天)
i am trying to detect S-wave in QRS complex and it works enough for me but i tryed for another ECG signal it dose not give me error buy the output of all procedure start from filtering to the end is NAn what is the wrong??

采纳的回答

Star Strider
Star Strider 2014-5-3
编辑:Star Strider 2014-5-3
The signal you posted is not the signal in the plot you posted. (I do congratulate you on getting your R and S detection routines to work!)
I needed to do some analysis of the signal you posted, because you did not provide us with the sampling frequency (that appears to be 1kHz), and there are 423 ‘NaN’ values I had to dispose of that initially prevented me from calculating the fft.
You have significant amplitude 50Hz powerline noise in your signal (if I’m correct about the sampling frequency). You have to filter that out first. Since all important EKG information is far below that, a simple lowpass filter should work. I will leave the design and implementation of that filter to you, but the Signal Processing Toolbox can do everything you need.
Remember to always look at your data before you process it. At least plot it if that is appropriate, and if necessary, do an fft, summary statistics, or other appropriate analyses.
Filter your signal, and if you have problems finding the peaks in the filtered signal, post that signal, describe your problems, and we will do our best to help.
  4 个评论

请先登录,再进行评论。

更多回答(2 个)

Hasan alomari
Hasan alomari 2014-5-3
this is the code and the ecg

Jan
Jan 2014-5-3
You can use the debugger to step through your code line by line to find out, in which operation the NaNs are produced. If you have specified the corresponding command and still have questions, you can post them again providing more information.