DAQ issue
显示 更早的评论
hello, i have a control script for a nidaq card which has been running well untill recently but has now decided to make troubles. i am under institutional pressure to find an urgent fix... please help!
the hadrware/software is as follows:
AdaptorDllName: 'C:\Program Files\MATLAB\R2010b\toolbox\daq\daq\private\mwnidaqmx.dll' AdaptorDllVersion: '2.17 (R2010b)' AdaptorName: 'nidaq' BoardNames: {'USB-6229'} InstalledBoardIds: {'Dev1'} ObjectConstructorName: {'analoginput('nidaq','Dev1')' 'analogoutput('nidaq','Dev1')' [1x25 char]}
a simplified version of the script is:
AO=analogoutput('nidaq','Dev1'); chano=addchannel(AO,0:3); putdata(AO, [0 0 0 0]); start(AO);
the error message is:
??? To run in a hardware-clocked output mode, this hardware requires that at least 2 samples be queued using PUTDATA. You must pad your output with additional samples to use PUTDATA, or use PUTSAMPLE instead.
Error in ==> daqdevice.start at 62 start( daqgetfield(obj,'uddobject') );
obviously putsample doesnt work either and (putsample(AO, [0 0 0 0]);) produces:
??? Data must be queued using PUTDATA before starting.
Error in ==> daqdevice.start at 62 start( daqgetfield(obj,'uddobject') );
thank you very much. kind regards. otto
1 个评论
Sean de Wolski
2011-8-8
Obvious things to check: was nidaq card plugged in/found before you started MATLAB and has it been uninterrupted since starting?
采纳的回答
更多回答(1 个)
类别
在 帮助中心 和 File Exchange 中查找有关 Call Web Services from MATLAB Using HTTP 的更多信息
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!