Sample time setting for high frequency systems
1 次查看(过去 30 天)
显示 更早的评论
What sample time should I use when simulating a system operating at 100 kHz?
It seems to me that the typical 0.2 seconds would be to small.
Are there quidelines for determining the appropriate sample time?
0 个评论
回答(2 个)
Fangjun Jiang
2011-8-15
A 100kHz signal means its period is 10us. If the signal is a sine wave, you would need about 20 data points to represent a complete cycle of a sine wave with good quality. That means 0.5us is your maximum step size or sample time. 0.2 seconds is way bigger.
0 个评论
Stephen
2011-8-15
1 个评论
Fangjun Jiang
2011-8-15
Sure. The proper sample time should be determined by the need of the application. To measure the noise level and temperature of a living room, for example, could have quite different sample time.
另请参阅
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!