set parameter in the Condenser Evaporator (2P-MA) block in app Designer
2 次查看(过去 30 天)
显示 更早的评论
Hi,
I want to set a particular parameter (number of two-phase fluid tubes ) of the block 'Condenser Evaporator (2P-MA)' from App designer using a discrete knob. I wrote a code, which is similar when I set parameters for other blocks. However, when I run the app designer code and then I set a particular value using the knob, an error message appears in the code: 'Condenser Evaporator (2P-MA) block (mask) does not have a parameter named 'Number of two-phase fluid tubes' (please, see the image).
Do you know why is that happening, considering that the name of the parameter that I want to set is such one? Or such parameter has another name? Does it has to do with the block is masked?
Thanks in advance for your comments...
Regards,
Mauricio
0 个评论
回答(1 个)
Vinayak
2024-5-24
Hi Mauricio,
To list all parameters for the block, you can use the get_param command as follows:
get_param('RefrigerationSystem/Condenser','DialogParameters');
For Mask Parameters, use:
get_param('RefrigerationSystem/Condenser','MaskNames');
Note that you may need to rename the model, as spaces are not allowed in valid model names.
Alternatively, you can open the model in Simulink, double-click the block, and hover over the parameter to see its name in the tooltip.