What Happened to the SrcWorkspace Name-Value Input to the sim() Command?

11 次查看(过去 30 天)
The SrcWorkspace Name-Value pair argument to the sim() command seems to have disappeared going from 2020b to 2021a. I searched the 2021a Release Notes and could find no mention of its removal. Did I miss that in the ReleaseNotes? More importantly, how does one implement that functionality now?

回答(2 个)

Paul
Paul 2021-8-31
Looks like one has to use a Simulink.SimulationInput object as the input to the sim() command.
  1 个评论
Tamas Rozsa
Tamas Rozsa 2022-1-7
编辑:Tamas Rozsa 2022-1-7
True.
In fact, 'SrcWorkspace' is also buggy and does not work well with data dictionaries (see e.g. https://www.mathworks.com/matlabcentral/answers/367223-using-srcworkspace-with-data-dictionaries), so Simulink.SimulationInput seems to be the way to go.
Another reason to avoid 'SrcWorkspace' might be that it seems to have issues also when using with the parallel computing command 'parfor' (see e.g. https://www.mathworks.com/matlabcentral/answers/94215-how-can-i-set-the-source-workspace-to-caller-when-using-a-the-sim-command-from-a-function-in-simul).

请先登录,再进行评论。


Felipe Padua
Felipe Padua 2022-7-16
It's present in R2022a documentation.
  3 个评论

请先登录,再进行评论。