How to add programmatically second input to Scope block in Simulink
3 次查看(过去 30 天)
显示 更早的评论
Hello, I'm trying to add programmatically a second connection to the Scope block in Simulink, is there a way to do it ?
The error message:
Error using untitled4 (line 19)
Invalid Simulink object name: scope/2.
clc
open_system(new_system('test'));
add_block('simulink/Sources/Sine Wave','test/sine');
add_block('simulink/Commonly Used Blocks/Scope','test/scope');
add_line('test','sine/1','scope/1');
m = 0;
if m == 2
product = add_block('simulink/Commonly Used Blocks/Product','test/prod');
block1_handle = add_block('simulink/Commonly Used Blocks/Constant','test/const');
line2_handle = add_line('test','sine/1','prod/1');
line1_handle = add_line('test','const/1','prod/2');
line3 = add_line('test','prod/1','scope/2');
sim('test');
open_system('test/scope');
delete_block([product block1_handle line2_handle line1_handle line3]);
else
b1 = add_block('simulink/Commonly Used Blocks/Gain','test/gain');
l1 = add_line('test','sine/1','gain/1');
l2 = add_line('test','gain/1','scope/2');
sim('test');
open_system('test/scope');
delete_block([b1 l1 l2]);
end
0 个评论
回答(1 个)
Fangjun Jiang
2021-10-12
编辑:Fangjun Jiang
2021-10-13
specify 2 ports when you add the Scope block
add_block('built-in/Scope','test/scope','NumInputPorts', '2');
另请参阅
类别
在 Help Center 和 File Exchange 中查找有关 Simulink Functions 的更多信息
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!