Common KVA base for machines of different.

2 次查看(过去 30 天)
In my simulink model i intend to use two synchronous machines of different ratings (synchronous machine salient pole standard). I have the data sheet, in which impedance values (in pu) are given on the specific machine KVA and voltage base. Can i use those values directly in the model or i am suppose to convert the in a single common base values for the complete model.

采纳的回答

Joel Van Sickel
Joel Van Sickel 2021-11-15
Hello Shagun,
you specify the power and voltage rating for each motor seperately, so you do not need to convert to a common pu base.
regards,
Joel