Common KVA base for machines of different.

1 次查看(过去 30 天)
In my simulink model i intend to use two synchronous machines of different ratings (synchronous machine salient pole standard). I have the data sheet, in which impedance values (in pu) are given on the specific machine KVA and voltage base. Can i use those values directly in the model or i am suppose to convert the in a single common base values for the complete model.

采纳的回答

Joel Van Sickel
Joel Van Sickel 2021-11-15
Hello Shagun,
you specify the power and voltage rating for each motor seperately, so you do not need to convert to a common pu base.
regards,
Joel

更多回答(0 个)

产品


版本

R2017b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by