how to disable turn off signal in time scope using switch in simulink

12 次查看(过去 30 天)
Hello,
Is there a way to disable or turn off signal in time scope using a switch in simulink?
thank you

回答(1 个)

Shlok
Shlok 2024-9-12,5:28
Hi Ecom,
Yes, you can disable or turn off a signal in a Time Scope using a switch in Simulink. Here’s how you can achieve this:
  1. Place a Switch block in your Simulink model. This block will be used to control whether the signal is sent to the Time Scope or not.
  2. Connect the signal you want to control to first input of the Switch block. The other input can be a constant value or zero that you want to use when the signal is turned off.
  3. Now set the "Criteria for Passing" parameter in the Switch block. If you're using a logical signal (e.g., 1 for ON and 0 for OFF), set the threshold to 0.5 or an appropriate value based on your control signal.
  4. Connect a control signal (such as a logical signal) to the control input of the Switch block. This control signal can be created using a Constantblock, Step block, or any other block that can switch between inputs.
  5. Finally, connect the output of the Switch block to the Time Scope input.
This setup will allow you to control whether the signal is visible in the “Time Scope based on the value of the control signal. When the control signal meets the criteria set in the Switch block, it will pass the actual signal; otherwise, it will pass the default value.
To know more about the different blocks mentioned above, refer to the following documentation links:
Hope it helps.

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by