Discrete FIR Filter for Embedded Targets
2 次查看(过去 30 天)
显示 更早的评论
I noticed that the Sample Time in the Simulink Discrete FIR Filter block is programmable. Does that translate well over to the embedded target. The filter i'm creating will essential be used for analog inputs with different sample times, just want to make sure there won't be any surprises.
Thanks.
0 个评论
回答(2 个)
Kaustubha Govind
2011-2-22
The sample time parameter is typically only significant for simulation. For code generation, what matters is the relative rates of blocks in the system compared to the "base rate". There is no sample-time inlined into the code - you must write wrapper code that uses timers/interrupts to run the model "step" function at the appropriate base rate.
0 个评论
另请参阅
产品
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!