Simulink missed some of the time values during simulation?
4 次查看(过去 30 天)
显示 更早的评论
I simulate a performance of standard DC machine model (SimPowerSystems->Machines) and I use a pausing simulation block http://www.mathworks.de/help/toolbox/simulink/ug/f11-31373.html#f11-31548 but it doesn't work properly. For instance for pause value 2.55s the simulation doesn't pause at that time but continuing the simulation to the end.. If I set a pause value to 2.54 or 2.56 it works suitably. Why simulation doesn't pause at the time 2.55 (for any end time of the simulation)?
0 个评论
采纳的回答
Guy Rouleau
2011-9-19
See my post here:
For a variable step solver, you can specify additional output times you want the solver to take. In your case, you can add 2.55 and the solver will take a step at that time.
0 个评论
更多回答(2 个)
Nirmal Gunaseelan
2011-9-19
The time steps chosen by Simulink depends on the type of solver (and the system that is being solved) that you have chosen. You can use the Data Inport/Outport tab in the Configuration parameters settings of the model to see what are the time steps that Simulink chose for the current simulation. If you are depending on the time step values (what is your use case?), you should be using Fixed-step solver where you can explicitly set the time step jumps.
0 个评论
另请参阅
产品
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!