Error:Each physical network must be connected to exactly one Solver Configuration block. There is no Solver Configuration block connected to Physical Network with the following blocks

479 次查看(过去 30 天)
I had connected a solver configuration block in my model but these error is popping up when i connect a "current-Voltage simscape interface" block in my model.Kindly guide me in solving this problem. Thanking you, Saideep.

回答(4 个)

Yogeshwar Bala
Yogeshwar Bala 2018-10-6
Connect an "Electrical Reference" block to your ground line and add a Solver Configuration block with default value of f(x) = 0 to it.
  5 个评论

请先登录,再进行评论。


Behnam Mohammad
Behnam Mohammad 2020-1-15
What happens when you have multiple subsystems and each subsystem has an individual solver?

ever steeven nevarez cedeño
tengo un problema similar pero al reves el problema es cuando lo pongo

Joel Van Sickel
Joel Van Sickel 2024-6-10
This specific problem happens from the interface block. Those blocks are used to decouple simscape networks and if you look under the hood, you will see they are connected by simulink wires, not simscape wires. This means that if you use one, you will now have an additional simscape network, so you will need to add an additional simscape configuration block to the side of the network that doesn't already have one. Or you will need to add it to both sides if neither side has one.

类别

Help CenterFile Exchange 中查找有关 Variable Initialization 的更多信息

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by