Simscape Block Parameter not Tunable
2 次查看(过去 30 天)
显示 更早的评论
I wish to control a Simscape block parameter using the dashboard slider switch.
I select Temperature Source, but the slider switch does not recognize it as having a tunable parameter.
The only block I can link the switch to is the scope!
Are the dashboard elements not compatible with simscape ones?
0 个评论
采纳的回答
Pratyush Roy
2022-1-11
Hi Matthew,
Simscape run-time parameters are run-to-run tunable. Therefore, for Dashboard blocks linked to Simscape blocks, changing the dials during simulation does not affect the simulation results.
To use Dashboard blocks for run-to-run tuning of Simscape block parameters, we can designate the parameter as Run-time configurable, associate it with a workspace variable, and link the Dashboard block to the workspace variable. The link here might be helpful for more information.
Hope this helps!
3 个评论
Pratyush Roy
2022-1-12
Hi Matthew,
Currently setting a Simscape parameter to any other configuration other than "run-time" and then connecting it to a Dashboard block is a limitation. The issue of tuning Simscape Variables using Dashboard blocks is a known one and our developers will try to fix it in a future release.
To link a dashboard block to a workspace variable, consider defining a variable, say T, in the base workspace and set the Parameter value for temperature in the Temperature Source as T. Then the dashboard blocks can be linked to the variable T. Please refer to the image file attached for reference,
Hope this helps!
更多回答(0 个)
另请参阅
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!