Hello, I'm trying to tune PID controller in Simulink (system with delay). My "model" in Simulink looks like this:

I used Cohen-Coon method to find parameters of PID controller. Input parameters for PID controller are all right but when i start the simulation I keep getting these "not smooth" graphs (via picture) and I don't know why. I already tried to change model settings -> solver -> min and max step size but there is no difference.

I would be grateful for any help with this problem.
3 个评论
采纳的回答
Sam Chak
2022-4-9
The spikes in the your original output signal was caused by the derivative filter in the PID controller block. More accurately, it's because you tuned the PID control gains manually using the Cohen-Coon method and directly inserted these 3 values into the block, without taking the effect of the derivative filter (N = 100 by default) into account.
There are generally two approaches to handle this situation:
- Tune the filter coefficient until you obtain a desired smooth output.
- Use the Ideal PID controller instead.