Asynchronous Machine runs in reverse when no voltage is applied.
3 次查看(过去 30 天)
显示 更早的评论
Hello.
I use an Asynchronous Machine (SI) in Simulink to control a positioning system. But when I start the simulation the motor runs in reverse even if the voltage is not applied to the stator terminals. It does run in reverse when I connect Tm (including 0). I use present model 15 but whatever model I use it behaves like that. If the input is disconnected the motor is working properly.
2 个评论
Joel Van Sickel
2022-8-1
Can you share the model, or at least a screenshot? i have used a few of our Asynchronous Motor models and they work as expected when 0 volts is applied.
Regards,
Joel
采纳的回答
Joel Van Sickel
2022-8-8
The issue is that you are applying a non zero torque to the machine. This is a constant torque which will put a rotational force on your machine regardless of what the AC system voltage is doing. This is expected and appropriate behavior when Tm is non zero. If the input voltage is disconnected, any torque, no matter how small, will spin the motor. You will need to create a more detailed model of when torque is and is not applied externally. The model makes sense at first because the applied voltage is creating a torque greater than the external torque, so it spins the motor as you'd expect, but once the electrical torque is no longer applied, there is only the external mechanical torque of Tm which is spinning the motor.
Regards,
Joel
更多回答(0 个)
另请参阅
类别
在 Help Center 和 File Exchange 中查找有关 Motor Drives 的更多信息
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!