TASK Add a Pipe (IL) (Isothermal Liquids > Elements) and a second Reservoir (IL) block. I Am Unable to Complete it, keep showing Error while submitting

2 次查看(过去 30 天)
Error : Does the following block value match the plotted requirement?
Pipe (IL): mdot_A
  15 个评论
Asma Zahid
Asma Zahid 2022-10-28
移动:Cris LaPierre 2022-10-28
In 6.4 Task 3- Simscape OnRamp, I'm facing issue in last step how I get the plotted requirement?. Please guide.

请先登录,再进行评论。

采纳的回答

Cris LaPierre
Cris LaPierre 2022-8-9
编辑:Cris LaPierre 2022-8-9
I discovered this is a known issue. In the meantime, see this Answer for a workaround
In short, a default property in the Isothermal Liquid block has changed. Open the block properties and set the value of the Entrained Air > Volumetric fraction of entrained air property to zero.

更多回答(0 个)