While simulating model in Simulink I got error as "External input specified in the Configuration Parameters dialog box on the Data Import/Export page (or as an option to SIM command) to a model containing no root level input ports"
0 个评论
采纳的回答
Fangjun Jiang
2022-8-19
You specified input data, but there is no root level input ports, which means no input data is needed.
If you've done this manually or inadvertently, press Ctrl+E, select "Data Import/Export" on the left, un-check "Input" on the right.
5 个评论
Param
2023-2-4
I was actually using the "From Workspace" block since the beginning and had infact put the same input configurations [tout, u]. I had also specified the same in the "Data Import/Export page" of the model configurations, still I was getting the error.
However, I tried using the inport block, and it worked just fine.
Thanks a lot for your help.
更多回答(0 个)