Simscape thermal model for wire embedded in polymer

6 次查看(过去 30 天)
Hi everyone,
I am trying to model the temperature change of a wire embedded in a polymer material (see figure below). On the other hand, I would like to monitor the temperature change at the upper surface. My question is if it is possible to use the "Temperature Sensor" block to measure a specific point (e.g. the midpoint) of the temperature on the top side?
Thanks in advance
Ozan

回答(1 个)

Nirupama
Nirupama 2024-1-22
As far as I know, you cannot read the tempertaure at a specified location in a body using "Temperature Sensor" block. Simscape models are lumped parameter models, meaning that each block represents a "lumped" average state of a component. For example, volume of the tank block has an average temperature, rather than a distribution of temperatures. In some cases, like the pipe, a temperature distribution is assumed to calculate heat transfer accurately, but the state of the block is still just a lumped temperature value.
Regards,
Nirupama

类别

Help CenterFile Exchange 中查找有关 Elements 的更多信息

产品

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by