Artefacts when filtering a contiguous signal
1 次查看(过去 30 天)
显示 更早的评论
Hello,
I have a signal vector vec (54 sampling points). That looks like that:
vec = [5 8 10 8 5 3 1 3 5];
vec = [vec vec vec vec vec vec];
When I filter it with a lowpassfilter, it looks like that (Fig1):
Code for the filtering is:
h = fdesign.lowpass('fp,fst,ap,ast', 0.10, 1, 1, 60);
Hd = design(h, 'equiripple');
c = filter(Hd,vec);
plot(c);
Now, I want to split the sample in zwo sections and filter them separately. As a result, I want to get the same result as in Fig1.
I tried this code:
% design filter
h = fdesign.lowpass('fp,fst,ap,ast', 0.10, 1, 1, 60);
Hd = design(h, 'equiripple');
% split signal in two sections
vec1 = vec(1:27);
vec2 = vec(28:54);
% define numerator, denominator and initial conditions for filter delay
num = Hd.Numerator;
den = 1;
zi = vec1(end-2:end);
% filter the two sections
c1 = filter(num,den,vec1);
c2 = filter(num,den,vec2,zi);
% concatenate and plot the filtered sections
c = [c1 c2];
plot(c);
but get artefacts in the plot:
Could someone tell me what am I doing wrong?
Best regards,
Rocketman
0 个评论
采纳的回答
Jan
2022-9-15
编辑:Jan
2022-9-15
The final state of the filter parameters after the 1st block is not the value of the signal. Replace:
zi = vec1(end-2:end); % Nope
c1 = filter(num, den, vec1);
c2 = filter(num, den, vec2, zi);
by
[c1, zf] = filter(num, den, vec1);
c2 = filter(num, den, vec2, zf);
There are still tiny differences in the magnitude of 1e-15 caused by rounding, because the implementations differ slightly:
c1 = filter(Hd, vec);
c2 = filter(Hd.Numerator, 1, vec)
plot(c1 - c2)
更多回答(0 个)
另请参阅
类别
在 Help Center 和 File Exchange 中查找有关 Signal Generation and Preprocessing 的更多信息
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!