supply variable efficiency map to a hydraulic pump
4 次查看(过去 30 天)
显示 更早的评论
Hi All,
How can I input an efficiency map instead of a fixed value parameter for the fixed-displacement hydraulic pump model in simhydraulics?
Any ideas?
1 个评论
Junfei Tang
2016-2-4
You can have a look at this. I guess it might be similar to your issue: http://www.mathworks.com/matlabcentral/answers/44515#answer_208604
回答(1 个)
Yifeng Tang
2022-6-16
In newer versions of Simscape Fluids, the fixed-displacement pumps allow lookup tables as inputs to specify the efficiency as a function of pressure gain and rpm.
If those are not available to you, the way to implement this manually is via lookup table outside ideal source blocks. A diagram like below can be a starting point. It only cover the volumetric efficiency part and requires RPM as a signal input.
![](https://www.mathworks.com/matlabcentral/answers/uploaded_files/1034500/image.png)
If you want to couple it with the mechanical domain, as in the fixed-displacement pump block, you may add a torque source and a velocity sensor for that purposes. The input to the torque source will be calculated from the delta_P and mechanical efficiency lookup table. The output from the velocity sensor will be sent to the "pump".
0 个评论
另请参阅
类别
在 Help Center 和 File Exchange 中查找有关 Upgrading Hydraulic Models to Use Isothermal Liquid Blocks 的更多信息
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!