How to connect sine wave source to PMSM motor?
6 次查看(过去 30 天)
显示 更早的评论
I tried to connect three sine waves to PMSM motor but it is not connected. What is the problem with it.I have tried Data conversion block,PS- simulink conversion block & Simulink-PS conversion but it is still not connecting, what is missing?

4 个评论
Sam Chak
2022-10-19
Can you tell which block is that from the following list of blocks in the Simscape Electrical_Block/Electromechanical/Permanent Magnet Library?
回答(1 个)
Aditya Pahariya
2022-10-21
移动:Joel Van Sickel
2022-11-1
Hi,
According to the help documentation for the PMSM, Input ports A,B and C from the block ; SIMSCAPE>ELECTRICAL>SPECIALIZED POWER SYSTEM>ELECTRICAL MACHINE>PMSM, are the electric terminals, and the sine wave block generates the output signal of data type double.
But for this block, an electric signal is required as the input in the A,B and C terminals.
I assume you are trying to give three phase input to the ports A, B and C.
You can accomplish the same with the below configuration by using 3 AC voltage sources with the proper phase difference with the common Ground (attached image and model).

0 个评论