- XCP internal error: timeout expired, in response to XCP SYNCH command
- Error detected while trying to disconnect Simulink from target application.
- XCP error: XCP internal error: No server connected
Simulink error while running controller on hardware using arduino
50 次查看(过去 30 天)
显示 更早的评论
Hi,
I am controlling the speed of a motor (high encoder resolution) using Arduino simulink connection.
I am getting the following error at high speeds
- XCP internal error: timeout expired, in response to XCP SYNCH command
- Error detected while trying to disconnect Simulink from target application.
- XCP error: XCP internal error: No server connected
Please help me to solve this issue.
0 个评论
采纳的回答
Harshit Gupta
2022-11-17
Hi Aakash,
As per my understanding, you are getting the following errors while using Arduino with Simulink:
One possible reason for these errors in Arduino is configuring the Fixed step size too low. We generally use this configuration as "auto". Thus, changing this to "auto" or increasing the step size can resolve the error.
Please refer to the following documentation link for more information about step size: https://www.mathworks.com/help/simulink/gui/fixed-step-size-fundamental-sample-time.html
1 个评论
Harshit Gupta
2022-11-21
Additional Input- If the above error is not resolved by the solution provided, you can reduce the Baud rate in the external mode panel to see if the error gets resolved.
You can refer to the following link for more information on how to set the Baud rate for the Arduino Board using MATLAB: https://www.mathworks.com/matlabcentral/answers/443100-how-to-set-baud-rate-in-the-matlab-support-package-for-arduino
更多回答(0 个)