problem to solar maximum power for resistive load
11 次查看(过去 30 天)
显示 更早的评论

first figure showed power is 315.1w which is maximum power for this solar panel.
when I changed irradiance from 1000 to 500, figure as blow
How come the power is only 87.59w (load keeps unchanged)?
How can I always find maximum point power as load is fixed but irradiance or temperature varys?
thanks.
0 个评论
采纳的回答
Salah
2023-1-8
You have a constant load in the figure, and you are calculating the power P = IV, so changing the irradiance will always change the output current from the cell thus the voltage, which will vary the power calculated and the load will still be constant.
2 个评论
Salah
2023-1-9
You need a system with a feedback and a controller, a controller algorithm can be something like this: MPPT Algorithm - MATLAB & Simulink (mathworks.com)
更多回答(0 个)
另请参阅
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!