How to avoid determining P wave in PVC beat ?
    3 次查看(过去 30 天)
  
       显示 更早的评论
    
Hello
Please help..me.
i am use the code to detect p wave on ECG Signal.
 %%%P Peak detection
    a=Rloc(i,j)-90:Rloc(i,j)-10;
    m=max(y1(a));
    b=find(y1(a)==m);
    b=b(1);
    b=a(b);
    Ploc(i,j)=round(b);
    Pamp(i,j)=round(m); 
when pvc beat in signal  the p wave you take location , how can be avoid that please? and thanks.

0 个评论
采纳的回答
  Star Strider
      
      
 2023-1-21
        There is no true P-deflection preceding a PVC.  
That is essentially the definition of a Premature Ventricular Contraction or Premature Ventricular Complex (PVC), in which the ventricular contraction is initiated by the Prukinje fibers rather than the SA node.  That a P-deflection appears just prior to the following ectopic deflection does not mean that the P-deflection initiated the ectopic contraction.  Here, it appears simply to be a chance occurrence.  The PVC has an associated compensatory pause following it, in which the A-V node is depolarised and suppressed.  See Braunwald's Heart Disease, Single Volume, 12th Edition for a thorough discussion.  
.