the model created seems not to behave phisically correct: heat exchanger reduces both temperature of TL and moisture air.
it should heat up air, cooling down fluid instead.
  7 个评论
carlo ferro
carlo ferro 2023-5-26
That was a mistake I have corrected the day before yesterday with positive results. not it converges rapidly without issues. I am now moving to a TL_2P_MA system
Yifeng Tang
Yifeng Tang 2023-5-26
just summarized the discussion into "Answer". happy modeling!

请先登录,再进行评论。

采纳的回答

Yifeng Tang
Yifeng Tang 2023-5-26
Setting reasonable parameters to discribe the nominal conditions for the heat exchanger seem to resolve the issue. Pay particular attention to units and type of information needed (mass flow vs. volumetric flow). The port size matters as well because the local velocity calculated based on port size and mass flow is also part of the energy flow calculation.