Check Block Compatibility Error

4 次查看(过去 30 天)
wenjing cai
wenjing cai 2023-8-12
回答: Govind KM 2024-10-7
Message: The Product output and Accumulator data types are less than full precision, which is not supported for HDL code generation with the selected HDL Block Properties. The following full precision settings will be used for HDL code generation: Product output = fixdt(1,31,29), Accumulator = fixdt(1,37,29). You can set these data types to 'Inherit: Inherit via internal rule' to automatically use full precision settings in your model (recommended).
when I find the model SyncCorr, I find there doesn't have the option of Inherit :Inherit via internal rule',so what can I do to correct this problem?

回答(1 个)

Govind KM
Govind KM 2024-10-7
The Digital Filter block has been made obsolete. It is recommended to use the Discrete FIR Filter, Discrete Filter, Biquad Filter, or Allpole Filter blocks in its place.