impact of zero sequence inductance when applied pmsm model

8 次查看(过去 30 天)
how to identifid impact of zero sequence inductance where is applied in ipmsm model in delta connection.

采纳的回答

Sabin
Sabin 2023-9-27
If the delta-wound option is selected, then is no longer valid that the ia+ib+ic=0. Hence the external circuit can drive an out-of-balance set of currents. The impact of zero sequence inductance will depend on the external circuit. Considering that v0=Rsi0+L0(di0/dt) we can conclude that zero sequence inductance will have an impact in the transient regime such as sudden changes in load and can help to dampen the oscillations. I hope this helps.

更多回答(0 个)

社区

更多回答在  Power Electronics Control

产品


版本

R2023a

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by