impact of zero sequence inductance when applied pmsm model
3 次查看(过去 30 天)
显示 更早的评论
采纳的回答
Sabin
2023-9-27
If the delta-wound option is selected, then is no longer valid that the ia+ib+ic=0. Hence the external circuit can drive an out-of-balance set of currents. The impact of zero sequence inductance will depend on the external circuit. Considering that v0=Rsi0+L0(di0/dt) we can conclude that zero sequence inductance will have an impact in the transient regime such as sudden changes in load and can help to dampen the oscillations. I hope this helps.
更多回答(0 个)