PLC Coder does not support the usage of machine parented data. How can I solve it?

2 次查看(过去 30 天)
I am currently working on Stateflow (Simulink) to generate a PLC Code compatible with Rockwell.
I am currently facing incompatibility issue: PLC Coder does not support the usage of machine parented data objects. How can I solve it without deleting such data?
Thanks

采纳的回答

Shivang
Shivang 2023-9-4
Hi Alice,
I understand you're running into an issue regarding the usage of machine-parented data objects in Stateflow.
Note that starting in R2023a, Stateflow charts no longer support machine-parented data. You will need to convert machine-parented data to chart-parented data store memory.
You can run Upgrade Advisor to fix this issue. Upgrade Advisor will automatically check the model for instances of machine-parented data. You will then be presented with an option to "Upgrade model", which will create chart-parented data in the charts that use machine-parented data.
Hope this helps.
-Shivang

更多回答(0 个)

类别

Help CenterFile Exchange 中查找有关 Simulink PLC Coder 的更多信息

产品


版本

R2021a

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by